{"created":"2023-06-20T15:53:16.311578+00:00","id":7833,"links":{},"metadata":{"_buckets":{"deposit":"5a0af670-36eb-43ea-b3ac-b0dd9b09bb7e"},"_deposit":{"created_by":28,"id":"7833","owners":[28],"pid":{"revision_id":0,"type":"depid","value":"7833"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00007833","sets":["172:173:229"]},"author_link":["27721","27818","27817","27819","27873","27876","27875","27821","27874","27820"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2015-05-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"42","bibliographicPageStart":"37","bibliographicVolumeNumber":"32","bibliographic_titles":[{"bibliographic_title":"日本赤十字社和歌山医療センター医学雑誌"},{"bibliographic_title":"Medical journal of Japanese Red Cross Society Wakayama Medical Center","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"密封小線源治療(以後RALSとする)は高線量率小線源を体内に入れて放射線治療を行うため、線源が目的の位置に正確に移動し、決められた時間正確に停止することが重要である。当センターのRALSにおいて、これらの精度を検証した。結果は停止位置精度1㎜以内、停止時間精度誤差1%以内を示し、日本放射線腫瘍ガイドラインの基準値を満たした。","subitem_description_type":"Abstract"}]},"item_10001_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{}],"names":[{"name":"Kawamura, Yoshiki"}]},{"nameIdentifiers":[{}],"names":[{"name":"Yoshikawa, Masanori"}]},{"nameIdentifiers":[{}],"names":[{"name":"Inoue, Masato"}]},{"nameIdentifiers":[{}],"names":[{"name":"Kuchii, Nobutaka"}]},{"nameIdentifiers":[{}],"names":[{"name":"Tsutsui, Kazushige"}]}]},"item_10001_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"日本赤十字社和歌山医療センター"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1341-9927","subitem_source_identifier_type":"ISSN"}]},"item_10001_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"川村, 佳生"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"吉川, 方登"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"井上, 賢人"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"口井, 信孝"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"筒井, 一成"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2015-08-17"}],"displaytype":"simple","filename":"Vol.32 37-42p.pdf","filesize":[{"value":"2.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"Wakayama32_07","url":"https://redcross.repo.nii.ac.jp/record/7833/files/Vol.32 37-42p.pdf"},"version_id":"8e9e5d05-530b-4fbf-a5a3-f0382ba8ae0c"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"密封小線源","subitem_subject_scheme":"Other"},{"subitem_subject":"RALS","subitem_subject_scheme":"Other"},{"subitem_subject":"線源停止位置精度","subitem_subject_scheme":"Other"},{"subitem_subject":"線源停止時間精度","subitem_subject_scheme":"Other"},{"subitem_subject":"brachytherapy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"RALS","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"source stop position accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"source stop time accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"密封小線源治療装置における線源停止位置・時間精度の検証","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"密封小線源治療装置における線源停止位置・時間精度の検証"},{"subitem_title":"Verification of the source stop position / time accuracy in brachytherapy system","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"28","path":["229"],"pubdate":{"attribute_name":"公開日","attribute_value":"2015-08-17"},"publish_date":"2015-08-17","publish_status":"0","recid":"7833","relation_version_is_last":true,"title":["密封小線源治療装置における線源停止位置・時間精度の検証"],"weko_creator_id":"28","weko_shared_id":-1},"updated":"2023-06-20T19:31:32.959513+00:00"}