{"created":"2023-06-20T15:50:41.107276+00:00","id":3570,"links":{},"metadata":{"_buckets":{"deposit":"11291943-96a2-4cb7-ab70-32f8085aa11b"},"_deposit":{"created_by":29,"id":"3570","owners":[29],"pid":{"revision_id":0,"type":"depid","value":"3570"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00003570","sets":["99:64:159"]},"author_link":["8371","8230","298","286","285","8501","7675","300","8374","301","296","299","6880"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2003-03-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"67","bibliographicPageStart":"62","bibliographicVolumeNumber":"8","bibliographic_titles":[{"bibliographic_title":"徳島赤十字病院医学雑誌"},{"bibliographic_title":"Tokushima Red Cross Hospital Medical Journal","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"冠インターペンション時の逮位塞栓は再灌流不全現象を引き起こし、微小循環障害の原因となる。本年より末梢保護デバイスであるPercu Surge™ が使用可能となり末梢塞栓の予防が可能となった。今回我々は不安定狭心症に対しPercu Sure™を用いて良好な結果が得られた症例を経験したので報告する。症例は57歳、男性。毎朝の胸痛の精査目的で待機的に冠動脈造影を施行した。右冠動脈中間部および逮位部に高度狭窄病変を認めた。末梢塞栓が危倶されたためPercu Surge™を使用し、バルーンにて拡張後ステントを留置した。吸引した内容物は多量の白色のデブリであった。術後CPKの上昇なく経過良好である。","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifierScheme":"WEKO"}],"names":[{"name":"TOMOKANE, Takeshi"}]}]},"item_5_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"症例","subitem_heading_language":"ja"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島赤十字病院"}]},"item_5_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"徳島赤十字病院"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.tokushima-med.jrc.or.jp/hospital/medical/2003pdf/013.pdf","subitem_relation_type_select":"URI"}}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9878 ","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"友兼, 毅"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"日浅, 芳一"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"山口, 浩司"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"小倉, 理代"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"尾原, 義和"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"尾形, 竜郎"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"鈴木, 直紀"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"弓場, 健一郎"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"高橋, 健文"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"細川, 忍"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"岸, 宏一"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"大谷, 龍治"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-05-17"}],"displaytype":"simple","filename":"trchmj801_62-67.pdf","filesize":[{"value":"2.6 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf002368","url":"https://redcross.repo.nii.ac.jp/record/3570/files/trchmj801_62-67.pdf"},"version_id":"19db649b-9429-420f-9a14-f1cc3d386870"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"末梢保護","subitem_subject_scheme":"Other"},{"subitem_subject":"狭心症","subitem_subject_scheme":"Other"},{"subitem_subject":"PCI","subitem_subject_scheme":"Other"},{"subitem_subject":"distal protection","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"angina pectoris","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"PCI","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report"}]},"item_title":"右冠動脈狭窄に対し末梢保護デバイス(Percu SurgeTM)を使用した不安定狭心症の1例","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"右冠動脈狭窄に対し末梢保護デバイス(Percu SurgeTM)を使用した不安定狭心症の1例"},{"subitem_title":"A Case of Unstable Angina with Right Coronary Artery Stenosis Treated with Distal Protection Devise (Peucu Suege™)","subitem_title_language":"en"}]},"item_type_id":"5","owner":"29","path":["159"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-17"},"publish_date":"2013-05-17","publish_status":"0","recid":"3570","relation_version_is_last":true,"title":["右冠動脈狭窄に対し末梢保護デバイス(Percu SurgeTM)を使用した不安定狭心症の1例"],"weko_creator_id":"29","weko_shared_id":-1},"updated":"2023-06-20T22:06:37.303240+00:00"}