{"created":"2023-06-20T15:50:38.190749+00:00","id":3495,"links":{},"metadata":{"_buckets":{"deposit":"088b11a5-6a18-42ec-a58e-2ac2dbfb9e7f"},"_deposit":{"created_by":18,"id":"3495","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"3495"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00003495","sets":["99:64:181"]},"author_link":["8368","478"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-03-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"116","bibliographicPageStart":"112","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"徳島赤十字病院医学雑誌"},{"bibliographic_title":"Tokushima Red Cross Hospital Medical Journal","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"現在,侵襲的冠動脈造影に代わる非侵襲的な冠動脈造影法として冠動脈CT が注目されている.CT の技術的進歩に伴い,冠動脈CT の施行件数は飛躍的に増加している.当院では,2012年1月より,現在最多の検出器列を持つ東芝社製320列CT Aquilion ONE が導入された.このAquilion ONE はRotaition time0.35sec/rot,検出器幅は0.5mm×320列の体軸方向に最大160mm 幅での撮影が可能となっており,寝台を移動させることなく心臓全体を1回のスキャンで撮影できる.これにより今までのCT よりもアーチファクトの少ない画像が得られる.本稿では,この320列CT を使用しての冠動脈評価の診断精度について述べる.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifierScheme":"WEKO"}],"names":[{"name":"YONEKURA, Hironobu"}]}]},"item_5_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"臨床経験","subitem_heading_language":"ja"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島赤十字病院"}]},"item_5_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"徳島赤十字病院"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.tokushima-med.jrc.or.jp/hospital/medical/2013pdf/024.pdf","subitem_relation_type_select":"URI"}}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9878","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"米倉, 広宣"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-05-12"}],"displaytype":"simple","filename":"trchmj1801_112-116.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf002310","url":"https://redcross.repo.nii.ac.jp/record/3495/files/trchmj1801_112-116.pdf"},"version_id":"e7044e3c-c3a3-491b-8285-260690a9947e"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"冠動脈CT","subitem_subject_scheme":"Other"},{"subitem_subject":"320列CT","subitem_subject_scheme":"Other"},{"subitem_subject":"診断精度","subitem_subject_scheme":"Other"},{"subitem_subject":"coronary CT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"320-area detector CT","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Diagnostic accuracy","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report"}]},"item_title":"当院での320列CTを使用した冠動脈CTの初期報告","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"当院での320列CTを使用した冠動脈CTの初期報告"},{"subitem_title":"An initial report of coronary CT using 320-area detector CT at our hospital","subitem_title_language":"en"}]},"item_type_id":"5","owner":"18","path":["181"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-12"},"publish_date":"2013-05-12","publish_status":"0","recid":"3495","relation_version_is_last":true,"title":["当院での320列CTを使用した冠動脈CTの初期報告"],"weko_creator_id":"18","weko_shared_id":18},"updated":"2023-06-20T20:32:56.704027+00:00"}