{"created":"2023-06-20T15:50:37.524561+00:00","id":3479,"links":{},"metadata":{"_buckets":{"deposit":"18f11401-bcd0-428d-8d8d-e78a4f3a18af"},"_deposit":{"created_by":18,"id":"3479","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"3479"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00003479","sets":["99:64:181"]},"author_link":["348","345","346","347","190"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2013-03-25","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"39","bibliographicPageStart":"36","bibliographicVolumeNumber":"18","bibliographic_titles":[{"bibliographic_title":"徳島赤十字病院医学雑誌"},{"bibliographic_title":"Tokushima Red Cross Hospital Medical Journal","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"41年前に移植されたDelrin 製Bj\u0002rk-Shiley 弁の円盤破損による人工弁機能不全に対し,再弁置換術を要した1例を経験したので報告する.症例は74歳,女性.リウマチ性僧帽弁狭窄症に対して1971年(33歳時)にBj\u0002rk-Shiley 弁を用いた僧帽弁置換術が施行された.1982年に大動脈弁狭窄症の出現に対し,大動脈弁置換術(Omniscience 弁,21mm)が施行されが,大動脈弁位人工弁機能不全が出現したため,1994年に再大動脈弁置換術(Edwards-Tekna 弁,21mm)が施行された.以後良好に経過していたが,呼吸困難増悪および貧血の進行を認めたため,2012年7月に心不全の診断で入院となった.入院後,心エコー検査にて僧帽弁位人工弁機能不全による僧帽弁閉鎖不全症(以下MR)を指摘され,心不全の原因と考えた.心不全のコントロール後に,手術を施行した.4度目の開心術であり,心嚢内は強固に癒着していた.Bj\u0002rk-Shiley 弁はDelrin 製円盤の一部が欠損しており,長期使用に伴う弁の摩耗・破損がMR の原因と考えた.術後経過は良好であり,術後22日目に軽快し転院した.Delrin製円盤弁は現行のpyrolyte carbon製とは異なり,耐久性に問題があり,同様の症例の報告が散見される.厳重な経過観察が必要で,予防的な再弁置換も考慮すべきと考える.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifierScheme":"WEKO"},{"nameIdentifierScheme":"CiNii ID","nameIdentifierURI":"http://ci.nii.ac.jp/nrid/9000005853897"}],"names":[{"name":"MOTOKI, Tatsuo"}]}]},"item_5_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"症例","subitem_heading_language":"ja"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島赤十字病院"}]},"item_5_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"徳島赤十字病院"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.tokushima-med.jrc.or.jp/hospital/medical/2013pdf/008.pdf","subitem_relation_type_select":"URI"}}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9878","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"元木, 達夫"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"松枝, 崇"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"来島, 敦史"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"大谷, 享史"}],"nameIdentifiers":[{},{}]},{"creatorNames":[{"creatorName":"福村, 好晃"}],"nameIdentifiers":[{},{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-05-11"}],"displaytype":"simple","filename":"trchmj1801_36-39.pdf","filesize":[{"value":"781.9 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf002244","url":"https://redcross.repo.nii.ac.jp/record/3479/files/trchmj1801_36-39.pdf"},"version_id":"fa276337-f527-4ae7-a864-a87a39ebcbe2"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Bjork-Shiley弁","subitem_subject_scheme":"Other"},{"subitem_subject":"Delrin製円盤破損","subitem_subject_scheme":"Other"},{"subitem_subject":"人工弁機能不全","subitem_subject_scheme":"Other"},{"subitem_subject":"Bj\u0002rk-Shiley valve","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"Delrin disc","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"prosthetic valve dysfunction","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report"}]},"item_title":"僧帽弁位Delrin製Bjork-Shiley弁の円盤破損による人工弁機能不全に対する再弁置換術の1例","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"僧帽弁位Delrin製Bjork-Shiley弁の円盤破損による人工弁機能不全に対する再弁置換術の1例"},{"subitem_title":"Prosthetic Valve Dysfunction Resulting from a Bjo\u0002rk-Shiley Delrin Disc Fracture in the Mitral Position : A Case Report","subitem_title_language":"en"}]},"item_type_id":"5","owner":"18","path":["181"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-11"},"publish_date":"2013-05-11","publish_status":"0","recid":"3479","relation_version_is_last":true,"title":["僧帽弁位Delrin製Bjork-Shiley弁の円盤破損による人工弁機能不全に対する再弁置換術の1例"],"weko_creator_id":"18","weko_shared_id":18},"updated":"2023-06-20T22:05:07.052737+00:00"}