{"created":"2023-06-20T15:50:36.099073+00:00","id":3441,"links":{},"metadata":{"_buckets":{"deposit":"6c2f8f66-b919-4022-8aa1-33b179c17099"},"_deposit":{"created_by":18,"id":"3441","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"3441"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00003441","sets":["99:64:118"]},"author_link":["8265","8266"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2005-03-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"129","bibliographicPageStart":"125","bibliographicVolumeNumber":"10","bibliographic_titles":[{"bibliographic_title":"徳島赤十字病院医学雑誌"},{"bibliographic_title":"Tokushima Red Cross Hospital Medical Journal","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"アンギオ装置をシーメンス社製アンギオスタープラスに更新したことで広い撮影視野が可能となり,画像処理能力も格段に向上したため,本装置導入後のインターベンションはかなりの時間短縮となった.しかしイメージインテンシファイア(以下I・I)・撮像管を使用した本装置にはI・I 中心から9cm をこえると糸巻き歪み,そしてDSA 画像にはベーリンググレアによる骨陰影の残像が現れていた.そこでDSA画像からDA画像に変換もしくは撮影モードをパルスモードにすることでこれら現象を抑えるようにした.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifierScheme":"WEKO"}],"names":[{"name":"KATO, Kimio"}]}]},"item_5_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"臨床経験","subitem_heading_language":"ja"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島赤十字病院"}]},"item_5_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"徳島赤十字病院"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.tokushima-med.jrc.or.jp/hospital/medical/2005pdf/028.pdf","subitem_relation_type_select":"URI"}}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9878","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"加藤, 君夫"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-05-08"}],"displaytype":"simple","filename":"trchmj1001_125-129.pdf","filesize":[{"value":"764.3 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf002213","url":"https://redcross.repo.nii.ac.jp/record/3441/files/trchmj1001_125-129.pdf"},"version_id":"96891ff7-9a25-4e50-982e-05c2e8819bfa"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"糸巻き歪","subitem_subject_scheme":"Other"},{"subitem_subject":"ベーリンググレア","subitem_subject_scheme":"Other"},{"subitem_subject":"DSA 画像の残像","subitem_subject_scheme":"Other"},{"subitem_subject":"パルスモード","subitem_subject_scheme":"Other"},{"subitem_subject":"pincushion distortion","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"veiling glare","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"afterimage on DSA","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"pulse mode","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report"}]},"item_title":"当院のDSA 撮影装置の長所と問題点","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"当院のDSA 撮影装置の長所と問題点"},{"subitem_title":"Advantages and Shortcomings of the Angiography System Used at Our Hospital","subitem_title_language":"en"}]},"item_type_id":"5","owner":"18","path":["118"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-08"},"publish_date":"2013-05-08","publish_status":"0","recid":"3441","relation_version_is_last":true,"title":["当院のDSA 撮影装置の長所と問題点"],"weko_creator_id":"18","weko_shared_id":18},"updated":"2023-06-20T22:04:37.984038+00:00"}