{"created":"2023-06-20T15:50:34.586041+00:00","id":3403,"links":{},"metadata":{"_buckets":{"deposit":"a22dcd9d-024d-483a-8c20-cd74a53a1746"},"_deposit":{"created_by":18,"id":"3403","owners":[18],"pid":{"revision_id":0,"type":"depid","value":"3403"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00003403","sets":["99:64:116"]},"author_link":["8183","8184"],"item_5_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2007-03-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"156","bibliographicPageStart":"150","bibliographicVolumeNumber":"12","bibliographic_titles":[{"bibliographic_title":"徳島赤十字病院医学雑誌"},{"bibliographic_title":"Tokushima Red Cross Hospital Medical Journal","bibliographic_titleLang":"en"}]}]},"item_5_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Tl‐201心筋シンチ検査(以下心筋シンチと略す)の撮像に際して,Tl‐201のエネルギーピークは71keV と167keV の2ピークあり,1ピーク収集方法か2ピーク収集方法かを選択するのは,施設によって様々である.そこで当院では,1ピーク収集と2ピーク収集のエネルギーピーク設定の違いにより画像にあたえる影響について検討を行った.また,新施設になって2検出器ガンマカメラECAM(東芝社製)が導入され,ECAMを使用した心筋シンチの臨床画像がどのようなものかはまだ確認できていないので,従来の3検出器9300Aとの撮影プロトコルによる画像との比較検討もあわせて行った.その結果,両機種ともに1ピーク収集と2ピーク収集でのデータ的な違いは,少ししか見られなかったものの,二者択一による視覚的な評価では,9300A については,2ピーク収集の方が1ピーク収集に比べ,コントラスト分解能が優れていると評価された.一方ECAMについては,1ピーク収集の方が2ピーク収集に比べ,コントラスト分解能が優れていると評価された.また,ECAMと9300A との比較では,明らかに9300Aの方がコントラスト分解能において画像描出能が高いように思われた.ECAMでは,メーカー設定で行っており,収集条件や収集形式などの検討も何も定まっておらず,当院における最適条件を決定していく必要がある.","subitem_description_type":"Abstract"}]},"item_5_full_name_3":{"attribute_name":"著者別名","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"8184","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TAKEOKA, Takaaki"}]}]},"item_5_heading_23":{"attribute_name":"見出し","attribute_value_mlt":[{"subitem_heading_banner_headline":"臨床経験","subitem_heading_language":"ja"}]},"item_5_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"徳島赤十字病院"}]},"item_5_relation_17":{"attribute_name":"関連サイト","attribute_value_mlt":[{"subitem_relation_name":[{"subitem_relation_name_text":"徳島赤十字病院"}],"subitem_relation_type_id":{"subitem_relation_type_id_text":"http://www.tokushima-med.jrc.or.jp/hospital/medical/2007pdf/027.pdf","subitem_relation_type_select":"URI"}}]},"item_5_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"1346-9878","subitem_source_identifier_type":"ISSN"}]},"item_5_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"竹岡, 孝晃"}],"nameIdentifiers":[{"nameIdentifier":"8183","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2013-05-06"}],"displaytype":"simple","filename":"trchmj1201_150-156.pdf","filesize":[{"value":"650.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf002177","url":"https://redcross.repo.nii.ac.jp/record/3403/files/trchmj1201_150-156.pdf"},"version_id":"8784f394-840d-4064-a3cd-ebabfb81b3fb"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Tl‐201心筋シンチ検査","subitem_subject_scheme":"Other"},{"subitem_subject":"ガンマカメラ","subitem_subject_scheme":"Other"},{"subitem_subject":"エネルギーピーク","subitem_subject_scheme":"Other"},{"subitem_subject":"myocardial Thallium scintigraphy","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"gamma camera","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"energy peak","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"technical report","resourceuri":"http://purl.org/coar/resource_type/c_18gh"}]},"item_title":"Tl‐201心筋シンチ検査","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Tl‐201心筋シンチ検査"},{"subitem_title":"Myocardial Thallium Scintigraphy","subitem_title_language":"en"}]},"item_type_id":"5","owner":"18","path":["116"],"pubdate":{"attribute_name":"公開日","attribute_value":"2013-05-06"},"publish_date":"2013-05-06","publish_status":"0","recid":"3403","relation_version_is_last":true,"title":["Tl‐201心筋シンチ検査"],"weko_creator_id":"18","weko_shared_id":18},"updated":"2023-06-20T22:03:41.820659+00:00"}