{"created":"2023-06-20T15:59:59.157659+00:00","id":18178,"links":{},"metadata":{"_buckets":{"deposit":"99e6cb2d-fdc3-4034-a3b5-edb209257eb9"},"_deposit":{"created_by":49,"id":"18178","owners":[49],"pid":{"revision_id":0,"type":"depid","value":"18178"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00018178","sets":["561:562:567"]},"author_link":["68992","68996","68995","68993","68994"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-03","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"34","bibliographicPageStart":"33","bibliographicVolumeNumber":"30","bibliographic_titles":[{"bibliographic_title":"旭川赤十字病院医学雑誌"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"生後5日以内の新生児12名(男児7名、女児5名)を対象に、自動聴性脳幹反応機器MB11 with BERAphone(MB11)を用いた新生児聴覚スクリーニングを行い、その有用性について検討した。異常なしは11名、片側(右耳)異常ありが1名であった。片側異常ありの症例は2日後に再検査を施行したところ、異常なしと判定された。MB11と精密検査を両方検査できた4名では、両者の検査結果に乖離を認めなかったことから、MB11は新生児聴覚スクリーニング検査として有用である可能性が示唆された。","subitem_description_type":"Abstract"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0913-4417","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"大木, 健一"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"狩野, 匡裕"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"近藤, えり子"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"片山, 晴美"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"佐藤, 賢哉"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-05-27"}],"displaytype":"simple","filename":"asahikawa2017-11臨床8.pdf","filesize":[{"value":"952.8 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"asahikawa201712","url":"https://redcross.repo.nii.ac.jp/record/18178/files/asahikawa2017-11臨床8.pdf"},"version_id":"0bad859d-404b-4ced-aba1-17fadd7eb424"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"時間","subitem_subject_scheme":"Other"},{"subitem_subject":"*新生児スクリーニング","subitem_subject_scheme":"Other"},{"subitem_subject":"*聴知覚障害(診断)","subitem_subject_scheme":"Other"},{"subitem_subject":"*脳幹聴覚誘発電位","subitem_subject_scheme":"Other"},{"subitem_subject":"*診断用機器","subitem_subject_scheme":"Other"},{"subitem_subject":"費用節約","subitem_subject_scheme":"Other"},{"subitem_subject":"精密検査","subitem_subject_scheme":"Other"},{"subitem_subject":"ヒト","subitem_subject_scheme":"Other"},{"subitem_subject":"新生児","subitem_subject_scheme":"Other"},{"subitem_subject":"男","subitem_subject_scheme":"Other"},{"subitem_subject":"女","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験"}]},"item_type_id":"10001","owner":"49","path":["567"],"pubdate":{"attribute_name":"公開日","attribute_value":"2022-05-27"},"publish_date":"2022-05-27","publish_status":"0","recid":"18178","relation_version_is_last":true,"title":["新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験"],"weko_creator_id":"49","weko_shared_id":-1},"updated":"2023-06-20T17:45:52.841802+00:00"}