{"created":"2023-06-20T15:59:50.532186+00:00","id":17944,"links":{},"metadata":{"_buckets":{"deposit":"f630c58f-c421-414d-84aa-76b86b30309d"},"_deposit":{"created_by":29,"id":"17944","owners":[29],"pid":{"revision_id":0,"type":"depid","value":"17944"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00017944","sets":["95:28:655"]},"author_link":[],"control_number":"17944","item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2021-12-01","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"11","bibliographicPageStart":"6","bibliographicVolumeNumber":"41","bibliographic_titles":[{"bibliographic_title":"静岡赤十字病院研究報"},{"bibliographic_title":"Journal of Japanese Red Cross Shizuoka Hospital","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"2020年4月1日より診療用放射線に係る安全管理体制に関する規定が施行され,被ばく線量の記録と管理が義務化された.これに当たり当院では,GE社製の被ばく線量管理システム「DoseWatch」を導入し,2020年3月23日より運用を開始した.今回はその主な機能と診断参考レベル20201)( DRLs2020)と比較した結果について報告する.","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"静岡赤十字病院"}]},"item_10002_source_id_11":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0911-9833","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorAlternatives":[{"creatorAlternative":"Endo, Motoki","creatorAlternativeLang":"ja"}],"creatorNames":[{"creatorName":"遠藤, 基生","creatorNameLang":"ja"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2022-03-17"}],"displaytype":"simple","filename":"jrcsh4101_6-11.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"pdf008955","url":"https://redcross.repo.nii.ac.jp/record/17944/files/jrcsh4101_6-11.pdf"},"version_id":"d3f1ca0f-75e5-4ea9-a613-dd092cf25d7f"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"DRLs2020","subitem_subject_scheme":"Other"},{"subitem_subject":"CTDIvol","subitem_subject_scheme":"Other"},{"subitem_subject":"DLP","subitem_subject_scheme":"Other"},{"subitem_subject":"最適化","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"線量管理ソフトDoseWatchの主な機能と診断参考レベル2020との比較- CT検査 -","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"線量管理ソフトDoseWatchの主な機能と診断参考レベル2020との比較- CT検査 -","subitem_title_language":"ja"}]},"item_type_id":"10002","owner":"29","path":["655"],"pubdate":{"attribute_name":"PubDate","attribute_value":"2022-03-17"},"publish_date":"2022-03-17","publish_status":"0","recid":"17944","relation_version_is_last":true,"title":["線量管理ソフトDoseWatchの主な機能と診断参考レベル2020との比較- CT検査 -"],"weko_creator_id":"29","weko_shared_id":-1},"updated":"2023-12-07T01:49:35.000627+00:00"}