{"created":"2023-06-20T15:56:41.535197+00:00","id":13661,"links":{},"metadata":{"_buckets":{"deposit":"4997717b-7dd0-478c-acd7-19fdadcf2ba0"},"_deposit":{"created_by":41,"id":"13661","owners":[41],"pid":{"revision_id":0,"type":"depid","value":"13661"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00013661","sets":["340","340:341","340:341:505"]},"author_link":["49932"],"item_10001_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-03","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"75","bibliographicPageStart":"71","bibliographicVolumeNumber":"22","bibliographic_titles":[{"bibliographic_title":"高知赤十字病院医学雑誌"},{"bibliographic_title":"Medical Journal of Kochi Red Cross Hospital","bibliographic_titleLang":"en"}]}]},"item_10001_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"Study Objective\nTo compare the stroke volume variation (SVV) derived from VigileoTMFlotrac system with the\npulse pressure variation (PPV) under different ventilator settings.\nDesign\nProspective measurement study\nSetting\nOperating room in the university hospital\nPatients\n12 patients (ASA physical status 1-2) who underwent elective surgery\nMethods\nSimultaneous readings of SVV from VigileoTMFlotrac system and PPV while gradually increasing\nand then decreasing positive end-expiratory pressure (PEEP) from 0 to 15 cm H2O in 5 cm H2O\nincrements.\nMain Results\nSVV significantly increased with PEEP >10 cm H2O, being variously 6% ± 2% (PEEP = 0 cm H2O),\n8% ± 2% (PEEP = 5 cm H2O), 11% ± 6% (PEEP = 10 cm H2O), 17% ± 10% (PEEP = 15 cm H2O),\n11% ± 8% (PEEP = 10 cm H2O), 7% ± 3% (PEEP = 5 cm H2O), and 6% ± 1% (PEEP = 0 cm H2O).\nPPV values significantly increased at a PEEP of 15 cm H2O, being variously 7% ± 4% (PEEP = 0\ncm H2O), 8% ± 4% (PEEP = 5 cm H2O), 10% ± 4% (PEEP = 10 cm H2O), 13% ± 5% (PEEP = 15\ncm H2O), 10% ± 4% (PEEP = 10 cm H2O), 7% ± 4% (PEEP = 5 cm H2O), and 6% ± 3% (PEEP = 0\ncm H2O).\nConclusions\nSVV derived from VigileoTMFlotrac system was significantly increased under a PEEP of 10 and 15\ncm H2O, although PPV values were not significantly affected at a PEEP of 10 cm H2O and below.\nHence, SVV derived from VigileoTMFlotrac system might overestimate fluid responsiveness under\nPEEP > 10 cm H2O.\n","subitem_description_type":"Abstract"}]},"item_10001_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0919-7427","subitem_source_identifier_type":"ISSN"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"Koichi, Yamashita"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2018-06-20"}],"displaytype":"simple","filename":"2017高知赤十字病院医学雑誌_了-15.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"2017高知赤十字病院医学雑誌_了-15","url":"https://redcross.repo.nii.ac.jp/record/13661/files/2017高知赤十字病院医学雑誌_了-15.pdf"},"version_id":"6618760b-c735-45c3-845b-13fb94953a36"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"eng"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"journal article","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"Effects of respiratory settings on stroke volume variation derived from the Vigileo Flotrac system: comparison with pulse pressure variation(和訳中)","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"Effects of respiratory settings on stroke volume variation derived from the Vigileo Flotrac system: comparison with pulse pressure variation(和訳中)","subitem_title_language":"en"}]},"item_type_id":"10001","owner":"41","path":["340","341","505"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-06-20"},"publish_date":"2018-06-20","publish_status":"0","recid":"13661","relation_version_is_last":true,"title":["Effects of respiratory settings on stroke volume variation derived from the Vigileo Flotrac system: comparison with pulse pressure variation(和訳中)"],"weko_creator_id":"41","weko_shared_id":-1},"updated":"2023-06-20T18:55:16.499116+00:00"}