{"created":"2023-06-20T15:55:37.462175+00:00","id":12210,"links":{},"metadata":{"_buckets":{"deposit":"c57722d7-a5df-4a89-8f35-fe3db871b4e8"},"_deposit":{"created_by":39,"id":"12210","owners":[39],"pid":{"revision_id":0,"type":"depid","value":"12210"},"status":"published"},"_oai":{"id":"oai:redcross.repo.nii.ac.jp:00012210","sets":["98:61:420"]},"author_link":["16598","38431","548","32023","38432"],"item_10002_biblio_info_7":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2017-03-01","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"26","bibliographicPageStart":"23","bibliographicVolumeNumber":"40","bibliographic_titles":[{"bibliographic_title":"高山赤十字病院紀要"},{"bibliographic_title":"Japanese Red Cross Takayama Hospital","bibliographic_titleLang":"en"}]}]},"item_10002_description_5":{"attribute_name":"抄録","attribute_value_mlt":[{"subitem_description":"MRI検査では生体内金属によるメタルアーチファクトが顕著に出現するため、診断に有用な画像を取得することが困難な場合がある。当院ではこのような症例においてメタルアーチファクトの低減が可能となるsyngo WARPというソフトを導入した。メタルアーチファクトはシーケンスパラメーターを変更する事でも軽減が可能であるので、今回の実験ではTSE法を使用し、TE、受信バンド幅、空間分解能、スライス厚についてのアーチファクト低減効果と、VATによるアーチファクトの変化について検証した。実験では自作ファントム(3種類の金属)を用いて、上記のパラメーターを変化させたとき、周波数方向・位相方向それぞれにおいて短軸方向での歪み率を求めた。また実験の結果よりアーチファクト低減により効果のあったバンド幅、空間分解能の値を高値と低値で固定し、VATの値のみを変化させた。結果として、TEとスライス厚の変更ではあまり低減効果は認められなかったが、受信バンド幅、空間分解能の変更では効果が大きく認められた。VATの値が高値なほど歪み率、高信号アーチファクト共に減少するが、値を大きくするほど周波数方向へのボケが目立つことから、他のパラメーターも同時に変化させる必要があった。メタルアーチファクト低減効果のあるパラメーターを使用・変更することは画像劣化を伴うため、各パラメーターを組み合わせて少しでも画像劣化を防ぐ必要がある。実臨床での最適パラメーターの設定が今後の課題となった。","subitem_description_type":"Abstract"}]},"item_10002_publisher_8":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"高山赤十字病院"}]},"item_10002_source_id_9":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"0387-7027","subitem_source_identifier_type":"ISSN"}]},"item_10002_version_type_20":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"橋本, 翔太"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"北村, 裕貴"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"畑中, 信吾"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"岩佐, 成彦"}],"nameIdentifiers":[{}]},{"creatorNames":[{"creatorName":"山下, 光弘"}],"nameIdentifiers":[{}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2017-08-14"}],"displaytype":"simple","filename":"06橋本 翔太.pdf","filesize":[{"value":"13.9 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"takayama40_006","url":"https://redcross.repo.nii.ac.jp/record/12210/files/06橋本 翔太.pdf"},"version_id":"a9e61e25-faca-47a2-9808-989eb86cce98"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"MRI","subitem_subject_scheme":"Other"},{"subitem_subject":"WARP","subitem_subject_scheme":"Other"},{"subitem_subject":"VAT","subitem_subject_scheme":"Other"},{"subitem_subject":"メタルアーチファクト","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"メタルアーチファクト低減ソフト(WARP)を用いた生体内金属に対する効果の検討","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"メタルアーチファクト低減ソフト(WARP)を用いた生体内金属に対する効果の検討"}]},"item_type_id":"10002","owner":"39","path":["420"],"pubdate":{"attribute_name":"公開日","attribute_value":"2017-08-14"},"publish_date":"2017-08-14","publish_status":"0","recid":"12210","relation_version_is_last":true,"title":["メタルアーチファクト低減ソフト(WARP)を用いた生体内金属に対する効果の検討"],"weko_creator_id":"39","weko_shared_id":-1},"updated":"2023-06-20T19:05:11.060258+00:00"}