{"_buckets": {"deposit": "99e6cb2d-fdc3-4034-a3b5-edb209257eb9"}, "_deposit": {"created_by": 49, "id": "18178", "owners": [49], "pid": {"revision_id": 0, "type": "depid", "value": "18178"}, "status": "published"}, "_oai": {"id": "oai:redcross.repo.nii.ac.jp:00018178", "sets": ["567"]}, "author_link": ["68992", "68996", "68995", "68993", "68994"], "item_10001_biblio_info_7": {"attribute_name": "書誌情報", "attribute_value_mlt": [{"bibliographicIssueDates": {"bibliographicIssueDate": "2018-03", "bibliographicIssueDateType": "Issued"}, "bibliographicPageEnd": "34", "bibliographicPageStart": "33", "bibliographicVolumeNumber": "30", "bibliographic_titles": [{"bibliographic_title": "旭川赤十字病院医学雑誌"}]}]}, "item_10001_description_5": {"attribute_name": "抄録", "attribute_value_mlt": [{"subitem_description": "生後5日以内の新生児12名(男児7名、女児5名)を対象に、自動聴性脳幹反応機器MB11 with BERAphone(MB11)を用いた新生児聴覚スクリーニングを行い、その有用性について検討した。異常なしは11名、片側(右耳)異常ありが1名であった。片側異常ありの症例は2日後に再検査を施行したところ、異常なしと判定された。MB11と精密検査を両方検査できた4名では、両者の検査結果に乖離を認めなかったことから、MB11は新生児聴覚スクリーニング検査として有用である可能性が示唆された。", "subitem_description_type": "Abstract"}]}, "item_10001_source_id_9": {"attribute_name": "ISSN", "attribute_value_mlt": [{"subitem_source_identifier": "0913-4417", "subitem_source_identifier_type": "ISSN"}]}, "item_creator": {"attribute_name": "著者", "attribute_type": "creator", "attribute_value_mlt": [{"creatorNames": [{"creatorName": "大木, 健一"}], "nameIdentifiers": [{"nameIdentifier": "68992", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "狩野, 匡裕"}], "nameIdentifiers": [{"nameIdentifier": "68993", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "近藤, えり子"}], "nameIdentifiers": [{"nameIdentifier": "68994", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "片山, 晴美"}], "nameIdentifiers": [{"nameIdentifier": "68995", "nameIdentifierScheme": "WEKO"}]}, {"creatorNames": [{"creatorName": "佐藤, 賢哉"}], "nameIdentifiers": [{"nameIdentifier": "68996", "nameIdentifierScheme": "WEKO"}]}]}, "item_files": {"attribute_name": "ファイル情報", "attribute_type": "file", "attribute_value_mlt": [{"accessrole": "open_date", "date": [{"dateType": "Available", "dateValue": "2022-05-27"}], "displaytype": "simple", "download_preview_message": "", "file_order": 0, "filename": "asahikawa2017-11臨床8.pdf", "filesize": [{"value": "952.8 kB"}], "format": "application/pdf", "future_date_message": "", "is_thumbnail": false, "licensetype": "license_free", "mimetype": "application/pdf", "size": 952800.0, "url": {"label": "asahikawa201712", "url": "https://redcross.repo.nii.ac.jp/record/18178/files/asahikawa2017-11臨床8.pdf"}, "version_id": "0bad859d-404b-4ced-aba1-17fadd7eb424"}]}, "item_keyword": {"attribute_name": "キーワード", "attribute_value_mlt": [{"subitem_subject": "時間", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*新生児スクリーニング", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*聴知覚障害(診断)", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*脳幹聴覚誘発電位", "subitem_subject_scheme": "Other"}, {"subitem_subject": "*診断用機器", "subitem_subject_scheme": "Other"}, {"subitem_subject": "費用節約", "subitem_subject_scheme": "Other"}, {"subitem_subject": "精密検査", "subitem_subject_scheme": "Other"}, {"subitem_subject": "ヒト", "subitem_subject_scheme": "Other"}, {"subitem_subject": "新生児", "subitem_subject_scheme": "Other"}, {"subitem_subject": "男", "subitem_subject_scheme": "Other"}, {"subitem_subject": "女", "subitem_subject_scheme": "Other"}]}, "item_language": {"attribute_name": "言語", "attribute_value_mlt": [{"subitem_language": "jpn"}]}, "item_resource_type": {"attribute_name": "資源タイプ", "attribute_value_mlt": [{"resourcetype": "journal article", "resourceuri": "http://purl.org/coar/resource_type/c_6501"}]}, "item_title": "新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験", "item_titles": {"attribute_name": "タイトル", "attribute_value_mlt": [{"subitem_title": "新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験"}]}, "item_type_id": "10001", "owner": "49", "path": ["567"], "permalink_uri": "https://redcross.repo.nii.ac.jp/records/18178", "pubdate": {"attribute_name": "公開日", "attribute_value": "2022-05-27"}, "publish_date": "2022-05-27", "publish_status": "0", "recid": "18178", "relation": {}, "relation_version_is_last": true, "title": ["新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験"], "weko_shared_id": -1}
新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験
https://redcross.repo.nii.ac.jp/records/18178
https://redcross.repo.nii.ac.jp/records/181785fdb2826-5a5c-49f9-879f-62bb22eba864
名前 / ファイル | ライセンス | アクション |
---|---|---|
asahikawa201712 (952.8 kB)
|
Item type | 学術雑誌論文 / Journal Article(1) | |||||
---|---|---|---|---|---|---|
公開日 | 2022-05-27 | |||||
タイトル | ||||||
タイトル | 新生児自動聴性脳幹反応機器(MB11 with BERAphone)の使用経験 | |||||
言語 | ||||||
言語 | jpn | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 時間 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | *新生児スクリーニング | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | *聴知覚障害(診断) | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | *脳幹聴覚誘発電位 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | *診断用機器 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 費用節約 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 精密検査 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | ヒト | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 新生児 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 男 | |||||
キーワード | ||||||
主題Scheme | Other | |||||
主題 | 女 | |||||
資源タイプ | ||||||
資源タイプ識別子 | http://purl.org/coar/resource_type/c_6501 | |||||
資源タイプ | journal article | |||||
著者 |
大木, 健一
× 大木, 健一× 狩野, 匡裕× 近藤, えり子× 片山, 晴美× 佐藤, 賢哉 |
|||||
抄録 | ||||||
内容記述タイプ | Abstract | |||||
内容記述 | 生後5日以内の新生児12名(男児7名、女児5名)を対象に、自動聴性脳幹反応機器MB11 with BERAphone(MB11)を用いた新生児聴覚スクリーニングを行い、その有用性について検討した。異常なしは11名、片側(右耳)異常ありが1名であった。片側異常ありの症例は2日後に再検査を施行したところ、異常なしと判定された。MB11と精密検査を両方検査できた4名では、両者の検査結果に乖離を認めなかったことから、MB11は新生児聴覚スクリーニング検査として有用である可能性が示唆された。 | |||||